REOVIB MFS 268 HP

IP 54 oder IP 20, high-power version

High-power version of the REOVIB MFS 268 frequency-control device, can be used for mains voltages of 400 V with max. 8 or 16A output current and for mains voltages of 230 V with max. 

12, 16, 32A output current. Available as IP20 versions for installation in control cabinets and also as IP54 standalone units for 230 V and 12/16A.

Highlights
Technical Details
Highlights

We are also delighted to offer you a suitable control cabinet system with client specific requirements.Special designs of the REOVIB MFS 268 HP can also be implemented if required.

Unique Selling Point

  • Independent of the mains input frequency
  • Able to automatically determine the resonant frequency of the vibratory conveyor system (with additional vibration amplitude sensor) and regulate the vibration amplitude and  maintain a constant feedrate irrespective of load or changes in the mechanical system
  • Field bus interfaces: ProfiNet, EtherNet/IP, EtherCAT, CAN-Bus, ProfiBus, DeviceNet 
  • Available with UL/CSA approval (Optional)
  • Conveyor frequencies adjustable between 5…300 Hz
  • Mains voltage compensation with constant vibration amplitude
  • All settings can be made using the integrated display
  • Sinusoidal output current
  • Can be used on 230 V or 400 V mains input
  • User settings can be stored
  • Fill level/overflow control 
  • Versions available in various protection classes and connector options
  • MFS 269 HP is available with AC output signal for use with permanent-magnet armature.
Technical Detail
Mains input115/230 V Auto Detect115/230 V Auto Detect230/400 V Auto Detect
Mains frequency50 / 60 Hz +/- 3 Hz50 / 60 Hz +/- 3 Hz50 / 60 Hz +/- 3 Hz
Output voltage0…100/0…205 V0…100/0…205 V0…205/0…360 V
Output currentmax 12/16 Amax. 32 Amax. 8/16 A
Vibration frequency 5…150 Hz5…150 Hz (Optional 300 Hz)5…150 Hz (Optional 300 Hz)
Setpoint valueDisplay, Potentiometer , 0…10V, 0…20 mADisplay, Potentiometer , 0…10V, 0…20 mADisplay, Potentiometer , 0…10V, 0…20 mA
Status signal250 V changeover relay, 1A250 V changeover relay, 1A250 V changeover relay, 1A
Ext. Enable  24 V DC, Switch 24 V DC, Switch 24 V DC, Switch 
Valve output24 V, 150 mA (IP 54)
Sensor supply24 V DC24 V DC24 V DC
Setting Umin / Umax DisplayDisplayDisplay
Soft starting Adjustable 0…5 Sek.Adjustable 0…5 Sek.Adjustable 0…5 Sek.
Material flow controlPNP, 24 V DCPNP, 24 V DCPNP, 24 V DC
Coarse/fine controlXXX
Vibration amplitude regulationXXX
Resonant frequency searchXXX
Selectable timer functionxxx
Sensor time out monitorxxx
Mains voltage compensationXXX
Field bus interfacesEtherNet/IP, EtherCat,
CAN-Bus, Profibus-DP, DeviceNet
EtherNet/IP, EtherCat,
CAN-Bus, Profibus-DP, DeviceNet
EtherNet/IP, EtherCat,
CAN-Bus, Profibus-DP, DeviceNe