Regenerative harmonics filter IP55 (400V/50 Hz)
CNW 957 LCL filters are used especially in regenerative converters (AFE), but also for inverters for renewable energies. The main purpose of this filter is to eliminate the PWM frequencies for protect the supply network. Nominal Voltage: 400 V Rated current: 14 – 74 A
THREE-PHASE SINE FILTER IP55
CNW 933 Sinusoidal output current – save costs and trouble-free operation. For particularly long cable lengths of > 100m between inverter and motor the shielded cable for EMI suppression used can cause a capacitive coupling. A conventional motor choke can not provide sufficient damping in such cases.
THREE PHASE SINE FILTER
Sinusoidal output current – save costs and trouble-free operation. For particularly long cable lengths of > 100m between inverter and motor the shielded cable for EMI suppression used can cause a capacitive coupling. A conventional motor choke can not provide sufficient damping in such cases.
REOHM Series 155 – combination
As soon as an electric machine works as a generator (electric motor brake), the braking resistor protects the machine from an excessive voltage increase in the intermediate circuit. REO braking resistors achieve better heat dissipation and better impulse loading by filling heat transport media in the vicinity of the wound body.
REOHM Series 156(UL)
As soon as an electric machine works as a generator (electric motor brake), the braking resistor protects the machine from an excessive voltage increase in the intermediate circuit. REO braking resistors achieve better heat dissipation and better impulse loading by filling heat transport media in the vicinity of the wound body.
REOHM Series 156
As soon as an electric machine works as a generator (electric motor brake), the braking resistor protects the machine from an excessive voltage increase in the intermediate circuit. REO braking resistors achieve better heat dissipation and better impulse loading by filling heat transport media in the vicinity of the wound body.
REOHM Series 155
As soon as an electric machine works as a generator (electric motor brake), the braking resistor protects the machine from an excessive voltage increase in the intermediate circuit. REO braking resistors achieve better heat dissipation and better impulse loading by filling heat transport media in the vicinity of the wound body.
Compensation current transformer
WKO series Closed-loop converter The REO current transformers of the WKO series work according to the proven compensation principle and are suitable for measuring direct and alternating currents. The primary current generates the magnetic flux in the ferromagnetic core, which is compensated by a secondary coil. The current evaluation is realized with an electronic circuit and […]
Single-phase DC link reactor (1 wire)
CNW 891 Reduce grid disruptions – save energy costs. The intermediate circuit choke is used to smooth the intermediate circuit current and to reduce the network perturbations in voltage intermediate circuit converters.
Braking Resistors – REOHM BW 151
As soon as an electric machine works as a generator (electric motor brake), the braking resistor protects the machine from an excessive voltage increase in the intermediate circuit. REO braking resistors achieve better heat dissipation and better impulse loading by filling heat transport media in the vicinity of the wound body.
Single-phase line reactor 4% Uk
CNW 901 Reduce grid disruptions – save up to 20% on energy costs. A line reactor relieves the supply network by compensating for the harmonic reactive power. The harmonic harmonics and commutation notches are greatly reduced. The converter electronics and the intermediate circuit capacitors are protected by using a line choke. Starting currents and current peaks are reduced […]
Three-phase mains filters (3 lines)
CNW 114/690 Applications: Frequency converters for motor drives, wind power installations and power supply units Conforming to: VDE 0565-3 / IEC 950 / UL 1283 Test voltage: L-L 2100 V, DC 1s, L-PE 2700 V, DC 1s Overload: 1,5 x I 1 min/h Climatic category: DIN IEC 68 Teil 1 25/085/21